The product range may vary in different regions.20
Bewator offers the broadest range of card readers, keypads, and cards on the market with the
ability to satisfy most needs and environments. They are robust, durable and are suitable for all
environments, either through flush or single-surface mounting.
BC18 Magstripe Reader
Magstripe Card-only reader for use with Bewator Entro or Bewator Entro Lite.
Article Number: 21-147
Technical Data
Connect to multiboxif both indoor and outdoor readers are to be used.
Interfaces:
Connects to Entro door controller (Clock/data) or to Bewacard BC640.
Housing:
Cast metal with integrated 3 metre cable.
Environment:
Indoor or outdoor use (with heating unit VS18). In very exposed
locations, use SH1 protective cover.
Temperature:
-10 to +55 °C. (-20 heating unit VS18 installed).
Voltage:
5 V DC
Current:
40 mA.
Dimensions:
29 (W) x 124 (H) x 28 (D) mm
BC43 Magstripe reader with keypad
BC43 is a Card+PIN reader for Bewator Entro or Bewator Entro Lite. Two units can
be installed for indoor/outdoor use. The Keypad is equipped with background
illumination and for flush mounting use the BB4 flush mounting unit.
Article Number: 21-543
Technical data
Housing:
Zinc casting lacquered metallic paint finish with stainless steel keys
and security lock.
Environment:
Indoor or outdoor use.
IP Rating:
54
Temperature:
-35 to +50 °C
Voltage:
12 to 24 V DC. Powered from controller unit.
Current:
50 mA
Dimensions:
110 (W) x 160 (H) x 47 (D) mm
Inputs:
Tamper switch internal/external (normally closed).
Magnetic Stripe Readers & Keypads
BEWATOR ENTRO
M43 Keypad
The M43 for Entro is used in mainly two situations:
– If you only require the group code level in the system.
– Where you want to add a PIN code function to an existing Hands-Free reader like HF500.
Article Number: 31-115
Technical data
Housing:
Cast metal with stainless steel keys and security lock.
Environment:
Indoor or outdoor use (IP54 design). In very exposed locations, use
SH2 or SH1 rain cover.
Temperature:
-35 to +50 °C
Voltage:
12 to 24 V DC, Powered from controller.
Current:
50 mA
Dimensions:
80 (W) x 140 (H) x 40 (D) mm
Inputs:
Tamperswitch for internal alarm.
For flush mounting – use BB3 flush
mounting unit. Se page 64